Generators

3 Phase / 400V 50 HZ

EAB 900
  • Standby/Prime Power: 900 / 815 kVA 
  • Voltage/Frequency: 400 V / 50 Hz
  • Engine: Baudouin 12M26G900/5
  • Alternator: Stamford
  • L x W x H: 4800 x 1800 x 2980 mm
  • Dry Weight: 8128 kg
  • Fuel Tank Capacity: 1450 L / 8h
Make Enquiry
EAB 1000
  • Standby/Prime Power: 1000 / 900 kVA 
  • Voltage/Frequency: 400 V / 50 Hz
  • Engine: Baudouin 12M26G1000/5
  • Alternator: Stamford
  • L x W x H: 4800 x 1800 x 2980 mm
  • Dry Weight: 8518 kg
  • Fuel Tank Capacity: 1450 L / 8h
Make Enquiry
EAB 1110
  • Standby/Prime Power: 1110 / 1010 kVA 
  • Voltage/Frequency: 400 V / 50 Hz
  • Engine: Baudouin 12M26G1100/5
  • Alternator: Stamford
  • L x W x H: 4800 x 1800 x 2980 mm
  • Dry Weight: 8107 kg
  • Fuel Tank Capacity: 1450 L / 8h
Make Enquiry
EAB 1250
  • Standby/Prime Power: 1250 / 1150 kVA 
  • Voltage/Frequency: 400 V / 50 Hz
  • Engine: Baudouin 12M33G1250/5
  • Alternator: Stamford
  • L x W x H: 5450 x 2420 x 3320 mm
  • Dry Weight: 10746 kg
  • Fuel Tank Capacity: 2072 L / 8h
Make Enquiry
EAV 110
  • Standby/Prime Power: 110 / 100 kVA 
  • Voltage/Frequency: 400V / 50 Hz
  • Engine: Volvo TAD531GE
  • Alternator: Stamford
  • L x W x H: 2650 x 1100 x 1710 mm
  • Dry Weight: 1458 kg
  • Fuel Tank Capacity: 185 L / 8h
Make Enquiry
EAV 145
  • Standby/Prime Power: 145 / 132 kVA 
  • Voltage/Frequency: 400V / 50 Hz
  • Engine: Volvo TAD532GE
  • Alternator: Stamford
  • L x W x H: 2950 x 1100 x 1790 mm
  • Dry Weight: 1677 kg
  • Fuel Tank Capacity: 260 L / 8h
Make Enquiry
EAV 165
  • Standby/Prime Power: 165 / 152 kVA 
  • Voltage/Frequency: 400V / 50 Hz
  • Engine: Volvo TAD731GE 
  • Alternator: Stamford
  • L x W x H: 3525 x 1150 x 1980 mm
  • Dry Weight: 2104 kg
  • Fuel Tank Capacity: 325 L / 8h
Make Enquiry
EAV 200
  • Standby/Prime Power: 200 / 180 kVA 
  • Voltage/Frequency: 400V / 50 Hz
  • Engine: Volvo TAD732GE 
  • Alternator: Stamford
  • L x W x H: 3640 x 1300 x 2105 mm
  • Dry Weight: 2351 kg
  • Fuel Tank Capacity: 400 L / 8h
Make Enquiry
EAV 225
  • Standby/Prime Power: 225 / 205 kVA 
  • Voltage/Frequency: 400V / 50 Hz
  • Engine: Volvo TAD733GE  
  • Alternator: Stamford
  • L x W x H: 3640 x 1300 x 2105 mm
  • Dry Weight: 2498 kg
  • Fuel Tank Capacity: 400 L / 8h
Make Enquiry
EAV 275
  • Standby/Prime Power: 275 / 250 kVA 
  • Voltage/Frequency: 400V / 50 Hz
  • Engine: Volvo TAD734GE 
  • Alternator: Stamford
  • L x W x H: 3640 x 1300 x 2105 mm
  • Dry Weight: 2610 kg
  • Fuel Tank Capacity: 400 L / 8h
Make Enquiry
EAV 330
  • Standby/Prime Power: 330 / 300 kVA 
  • Voltage/Frequency: 400V / 50 Hz
  • Engine: Volvo TAD1341GE 
  • Alternator: Stamford
  • L x W x H: 4300 x 1500 x 2385 mm
  • Dry Weight: 3434 kg
  • Fuel Tank Capacity: 515 L / 8h
Make Enquiry
EAV 350
  • Standby/Prime Power: 350 / 318 kVA 
  • Voltage/Frequency: 400V / 50 Hz
  • Engine: Volvo TAD1341GE 
  • Alternator: Stamford
  • L x W x H: 4300 x 1500 x 2385 mm
  • Dry Weight: 3529 kg
  • Fuel Tank Capacity: 515 L / 8h
Make Enquiry

Standard Specifications

Frequently Asked Questions

Please reach us at easales@eapowers.com if you cannot find an answer to your question.

A totalizing panel (more commonly referred to as a synchronizing panel) is a centralized electrical control system used to manage, synchronize, and combine the electrical outputs of two or more generator sets (gensets) into a single, unified power supply. Instead of multiple generators running independently to power separate sections of a building, a totalizing panel aggregates their capacities onto a common busbar, allowing them to act as a virtual single unit to handle heavy electrical loads

Why Facilities Use Totalizing Panels?

Using a totalizing panel to combine smaller generator sets is highly favored over relying on a single, massive generator. If a single massive unit fails, the entire facility loses power. In a parallel configuration managed by a totalizing panel, if one generator goes down, the remaining units stay active to support the most critical loads. This creates system redundancy and maximizes uptime in high-stakes environments like data centers, hospitals, and heavy industrial facilities.

A silent generator is engineered to reduce both engine noise and vibration while maintaining reliable power output. Key noise-control features typically include:

  • Acoustic enclosure: A weather-resistant, sound-attenuated canopy lined with noise-absorbing and fire-retardant materials.
  • Critical-grade exhaust silencer: Reduces the sound produced by exhaust gases without significantly restricting engine performance.
  • Anti-vibration mounts: Isolate the engine and alternator from the base frame, limiting structure-borne noise.
  • Optimized cooling system: Low-noise fans, carefully designed airflow paths, and acoustic air inlets and outlets reduce cooling noise while preventing overheating.
  • Sealed access doors: Compression seals and insulated panels help stop sound from escaping through gaps in the enclosure.
  • Rigid base frame: A strong, accurately aligned structure minimizes vibration, resonance, and mechanical noise.
  • Advanced engine control: Stable speed regulation and efficient combustion help the diesel generator operate smoothly under changing loads.
  • Remote radiator options: Where extremely low sound levels are required, the cooling system can be installed away from the generator set.

Together, these features make an enclosed diesel generator suitable for hospitals, hotels, residential buildings, schools, offices, and other noise-sensitive locations. When selecting a silent generator, buyers should compare the guaranteed sound-pressure level in dB(A), the measurement distance—commonly 1 or 7 metres—and the generator’s rated load during testing.

A quiet generator, should combine effective sound attenuation with sufficient ventilation, safe operating temperatures, straightforward maintenance access, and dependable performance.

A standby generator functions as an automatic backup power system. When it detects a disruption in the main electrical supply, the generator's automatic transfer switch activates, starting the generator almost instantly. It then begins supplying power to predetermined circuits and appliances. This seamless operation ensures there is minimal disruption in power availability, making it indispensable in maintaining continuous electrical service during unexpected outages or emergencies. Once the regular power grid is restored, the generator shuts off, and the transfer switch reconnects your system to the main power supply.

Standby and prime ratings are critical performance indicators for generator sets, reflecting their operational capabilities under different conditions. Prime rated generators are designed to operate continuously, supplying power for an unlimited number of hours each year. They are ideal for applications with no constant utility source, such as remote construction sites or events. Standby rated generators, on the other hand, are intended for emergency use, typically providing power during utility outages. They are not designed for continuous use but can operate for shorter periods, typically up to 500 hours annually. The rating helps users select the appropriate generator based on expected usage patterns, ensuring efficiency and longevity of the generator set.

We serve a variety of industries including manufacturing, healthcare, commercial buildings, data centres, and more. We supply a wide range of diesel generator sets including industrial diesel generators, emergency backup generators, and commercial diesel generators. Our portfolio also features customized Diesel generators suitable for various applications such as hospitals, construction sites, and remote locations.

We offer comprehensive diesel generator installation and commissioning services. Our expert team is also equipped to handle all aspects of diesel generator maintenance and repairs, ensuring your generator operates efficiently and reliably.

Regular maintenance is crucial for the longevity and efficiency of your diesel generator. This includes routine checks and servicing, which can be scheduled with our team. Our blog also offers detailed guides on how to maintain your diesel generator. 

Yes, all our generator sets are manufactured in strict accordance with UK Standards, ensuring high-quality, reliability, and safety. Adhering to these standards guarantees that each generator meets rigorous regulatory requirements for performance and environmental impact. This compliance not only enhances the durability and efficiency of our generators but also provides our customers with peace of mind, knowing they are investing in equipment that adheres to the highest standards of manufacturing excellence recognized in the UK and globally. 

We prioritize safety in all of our projects. We follow UK industry standards and regulations to ensure a safe work environment for our employees and clients.

You can buy our diesel generators directly contacting us by phone mail or by visiting our sales offices across the UK. We provide a variety of generators tailored to meet the specific needs of both large-scale industrial applications and small businesses.

Chat with us on whatsapp